Hemodynamic response to fluid removal during hemodialysis: categorization of causes of intradialytic hypotension
Conclusion: Intradialytic noninvasive cardiac output measurement has enabled the assessment of changes in cardiac power and peripheral resistance. These have been demonstrated to be distinctly different causes of hypotensive episodes in routine dialysis patients. This information can potentially improve the care of dialysis patients prone to IDH, by interventions based on the specific causes.